Coming soon
Zigbee via the Clume panel
A Crestron Home platform driver that brings the Zigbee devices of a Clume panel's own Zigbee network into Crestron Home as child devices. The Clume panel is the Zigbee hub and talks to the driver on the local network.
What it does
- A Clume panel is the Zigbee coordinator and connects to the driver on port 9534.
- Publishes the panel's Zigbee devices as children: on/off lights or appliances, dimmable, tunable-white and colour lights, contact, temperature and humidity sensors, lock, shade, occupancy, water leak, smoke, CO and motion.
- Its own settings page on port 9534, opened from Configure Pro for one hour and protected by a PIN: zones, pairing, room placement, names and settings, Identify and Reconfigure.
- More than one zone (one hub panel per zone), and Zigbee routers.
- A network map of the Zigbee mesh, with link signal. It works offline.
- Occupancy events (Occupied, Vacant, and Vacant after 1 to 30 minutes), and optional temperature and humidity values for Configure Pro conditions.
- Device cards show last heard, signal, power source and battery. Battery low shows on the tile.
- A full network backup per zone, downloaded from the page. Last known values are kept across a restart or update.
Devices and protocols
- Zigbee, through a Clume panel as the coordinator
- Lab devices: SONOFF SNZB-06P presence sensor, SONOFF ZBM5-2C-80/86 two-gang switch, SNZB-02P temperature and humidity sensor
- A Clume 4 panel as the hub and a Clume 7 panel as a router
- Crestron Home on a CP4-R
Requirements
- A Crestron Home processor; the lab uses a CP4-R. The driver declares SDK 21 or later.
- A Clume panel with the Zigbee hub firmware. The network map needs hub firmware with link contract 1.3.
- Zigbee devices paired to the panel's network.
- A browser on the home network, for the settings page.
Limits to know before you install
- Works only with Clume panels as the hub, not with other Zigbee coordinators.
- No full list of supported devices yet.
- Backup download works; restore from a backup is switched off for now.
- The settings page is plain HTTP, for the home's own network only.
- The page cannot create a Crestron room.
- Whether a shade shows in the Crestron Home app is not yet proven. Several built features still owe a lab check.
- Temperature and humidity values for Configure Pro take effect only after a driver restart or a new placement.
- A version change gives the driver a new data folder: export before an update.